TH Series HEPA Terminal Hood Filter
TH Series HEPA Terminal Hood Filter Housing: Advanced Air Sterility for EMEA Infrastructure
In the rapidly expanding urban landscapes of Europe and the Middle East, maintaining superior Indoor Air Quality (IAQ) is no longer optional—it is a critical safety requirement. The TH Series HEPA Terminal Hood Filter is a high-performance solution engineered to protect people, processes, and sensitive equipment in the world’s most demanding environments.
From the sterile surgical suites of Riyadh and Berlin to the high-traffic transit hubs of Dubai and London, the TH Series provides a robust barrier against airborne contaminants, pathogens, and fine particulates.
Engineered for Critical Environments
The TH Series HEPA Terminal Hood Filter is a versatile, fully integrated filtration housing designed for both supply and exhaust applications. Its fully welded body ensures absolute airtightness, preventing any unfiltered air bypass—a necessity for modern “Smart City” infrastructures.
Key Applications Across the EMEA Region
Healthcare & Pharma: Ensuring ISO-compliant sterility in operating theaters, oncology wards, and cleanroom manufacturing.
Data Centers: Protecting sensitive server components from microscopic dust and corrosive particulates in arid Middle Eastern climates.
Aviation & Transit: Providing high-volume, clean air for millions of travelers in international airports and metro stations.
Food & Beverage: Maintaining aseptic conditions in high-output production lines across the European Union.
__________________________________________________________________________________________________________________________________________
Technical Excellence & Compliance
Leak-Proof Integrity: Every unit undergoes a rigorous Vent Integrity Test in accordance with ISO 14644-3, ensuring the housing maintains a perfect seal under operational pressure.
- Advanced Media Technology: Equipped with mini-pleated HEPA or ULPA filters using ultrafine fiberglass media for maximum surface area and minimal resistance.
- Customizable Connectivity: Duct connections are fully adaptable to meet specific architectural requirements, whether for new builds or retrofitting legacy structures.
- Durable Construction: Built to withstand the humidity of coastal Europe and the extreme heat of the Middle East without compromising structural integrity.
______________________________________________________________________________________________________________________________________________
Our Key Features
- Durable aluminium or stainless steel frame
- Robust and lightweight construction.
- Available with polyurethane or EPDM gaskets for superior sealing
- H13, H14, U15, and U16 filtration efficiency
- Hot melt technology pleat spacing
- up to 75°C with a relative humidity of 95%
- various sizes to accommodate different airflows and applications.
- Specifically designed for cleanroom environments,
- Contamination-free air distribution
Application
- Ideal for use in clean rooms
- Laboratories
- Pharmaceutical manufacturing
- Food and beverage processing
- Hospital environments
Construction
- HEPA/ULPA laminar flow Diffuser-Filter H14
- Frame: Extruded and anodized aluminium profile
- Filtering Element: Glass microfiber paper
- Separators: Thermoplastic glue beads
- Sealant: Polyurethane
- Protective grid: Steel grid at the air outlet; white epoxy painted
- Gasket: Component polyurethane liquid system. (Semi-circular expanded polyurethane)
- Collar: Ext. collar 200, 250 and 315 mm. (according to model).
- MPPS Efficiency: 99.995% and 99.9995%
- Class EN 1822: H14 and U15
- Recommended Final Pressure Loss: 600 Pa.
- Temperature: 80ºC in continuous service
______________________________________________________________________________________________________________________________________________
Frequently Asked Questions (FAQ)
1. Why is the TH Series preferred for Metro Stations and Airports?
High-traffic transit hubs deal with significant levels of “black carbon” and brake dust. The TH Series provides a terminal barrier that ensures the air delivered to passenger lounges and platforms is free from these harmful particulates, meeting the highest public health standards.
1. Why is Terminal HEPA Housing critical for Data Centers?
In data centers, particulate matter can cause “zinc whiskers,” hardware corrosion, and overheating. By using Terminal HEPA housings, you provide a final barrier that ensures cooling air is free of microscopic dust. This is especially vital in the Middle East, where fine desert sand can bypass standard pre-filtration.
2. Does the TH Series comply with European Cleanroom Standards?
Yes. The TH Series is factory-tested and validated against ISO 14644-3 and EN 1822. This makes it fully compliant for use in European pharmaceutical labs and hospitals that require documented proof of air tightness and filtration efficiency.
3. Can the duct connections be customized for specific project needs?
Absolutely. We understand that HVAC layouts in historic European buildings or modern Middle Eastern skyscrapers vary. The TH Series offers adaptable duct connections (top or side entry) to ensure seamless integration into your specific ventilation design.
4. What is the benefit of a “Fully Welded Body”?
A fully welded body eliminates the risk of air leakage through joints or rivets. This is vital in containment applications (like infectious disease wards) where the escape of a single pathogen could compromise the entire facility’s safety.
5. What sealing options are available for the filters?
We offer two primary sealing methods to meet different regional and industry standards:
PU Gasket Seal: Standard for most European commercial and hospital applications.
GEL Seal (Knife-edge): Often preferred in pharmaceutical and high-containment labs for an extra layer of leak protection and easier filter changes.