...
bg1

Ga-Force X: Precision Coalescing for High-Velocity Gas Streams

Contamination in gas streams whether in the form of fine liquid aerosols, sub-micron oil mists, or condensed water is the primary cause of downstream equipment failure. The Ga-Force X Gas Coalescing Filter Cartridge series is K Filter’s premier coalescing solution, specifically engineered to merge fine droplets into manageable liquids for easy removal.

Leveraging 27 years of engineered mastery, the Ga-Force X Gas Coalescing Filter Cartridge ensures your gas streams are “instrument-quality,” protecting high-value assets like gas turbines, compressors, and sensitive pneumatic controls.

Connect Now! | Contact Us


Engineered for Extreme Gas Processing

The Ga-Force X Gas Coalescing Filter Cartridge isn’t just a filter; it’s a mechanical separator designed for the “High-Force” environments of modern energy production:

  • Aerosol & Mist Elimination: Utilizing a multi-layer borosilicate microfiber matrix to capture aerosols as small as 0.3 microns with up to 99.99% efficiency.
  • Structural Rigidity: Built with a reinforced stainless steel inner and outer core to prevent media collapse during sudden pressure surges or high differential pressure (ΔP).
  • High-Flow Geometry: The specialized fiber orientation allows for maximum gas throughput while maintaining low resistance, significantly reducing energy costs for compression.

“Don’t pay for the name on the box; pay for the purity in the pipe.”

Unlike the “Big Brands,” we offer a Technical Consultation Service. If you are currently using a Pall PhaseSep or a PECO PCHG, our engineers don’t just look at a cross-reference table. We look at your flow rates, viscosity, and chemical composition to ensure the K Filter element out-performs the original equipment.

The Ga-Force X is the trusted choice for:

  • Natural Gas Processing: Removing lube oil carryover from compressors.
  • Gas Turbine Protection: Eliminating moisture and particulates before combustion to prevent blade erosion.
  • Compressed Air Systems: Providing ultra-clean, oil-free air for pneumatic instrumentation.
  • Refinery Fuel Gas: Removing liquid hydrocarbons to ensure clean burner operation.
FeatureEngineering Benefit
Media TypeHigh-Efficiency Borosilicate Micro-Glass
Efficiency99.9% Removal of Aerosols & Solids
Purity LevelDown to 0.3 Microns
ConstructionAISI 304/316L Stainless Steel Supports
StandardISO 8573-1 Class 1 Quality Air/Gas

Why K Filter is a “Smart Substitute”:

1. Engineering Parity (The Beta 5000 Standard)

Most competitors (like Pall and Parker) set the industry benchmark at 99.98% efficiency. The Ga-Force X Gas Coalescing Filter Cartridge matches this standard by using a similar multi-layer borosilicate microfiber matrix, ensuring that you don’t sacrifice gas purity for a better price.

2. Structural “Drop-In” Compatibility

Our cartridges are designed to fit the specific seating mechanisms of these brands, including:

  • Single Open End (SOE) with 222 or 226 O-ring codes.
  • Double Open End (DOE) with flat gaskets.
  • Self-Centering Guides used in large PECO and Jonell horizontal housings.

3. Overcoming “Media Disarming”
our Hy-Sepra X uses advanced surface treatments. In liquid-liquid applications (like diesel de-hazing), surfactants in the fuel can “disarm” standard glass fiber filters, causing them to stop coalescing. K Filter uses treated media to resist disarming, maintaining a “Bright & Dry” product for longer cycles.

4. Cost-to-Performance Advantage
While PECO and Pall often carry a “brand premium” price, K Filter offers the same 93°C temperature ratings and -bar differential pressure strength at a significantly more competitive price point, backed by our 27 years of engineered mastery.

How to Request a Crossover:
To ensure a 100% accurate match, simply provide us with the competitor part number (e.g., PCHG-336 or CS604LGH13). Our engineering team will verify the micron rating, seal compatibility, and flow capacity to ensure the Ga-Force X or Hy-Sepra X performs identically or better in your system.

FAQ: Ga-Force X Coalescing Technology


Q: is it substitute with PECO,Parker,Pall and Jonell filters ?
Yes, the Ga-Force X and Hy-Sepra X series are designed as high-performance equivalents and substitutes for the industry’s major brands. Because K Filter utilizes universal industrial dimensions (standard IDs, ODs, and lengths) and high-specification materials (Borosilicate and 316L Stainless Steel), these cartridges can be used as direct “drop-in” replacements without requiring any modifications to your existing filter vessels.

K Filter SeriesSubstitute for PECO*Substitute for Pall*Substitute for Parker*Substitute for
Jonell*
Ga-ForceX (Gas
Coalescing)
PEACH PCHG / j-Ceptor 330SepraSol™ / SepraSol PlusOIL-X / Zander / do
mnick hunter
JPMG / JPM602(Mi
croglass)
Hy-SepraX (Liquid-Liquid)DynaSep™ / Dyna CeptorAquaSep®XS /  PhaseSep®IC series / V-SeriesJLL / JLS (Liquid Separator)

Q: How does the Ga-Force X differ from a standard particulate filter?
A:
While a particulate filter only stops solid debris, the Ga-Force X uses a specialized “Inside-to-Outside” flow pattern. This forces fine liquid aerosols to collide and grow into larger droplets (coalescence) that then drain to the bottom of the housing for removal.

Q: What is the maximum operating temperature for the Ga-Force X?
A:
Depending on the seal and support material, the standard Ga-Force X operates efficiently up to 150°C. For higher thermal requirements, we offer custom configurations using specialized binders.

Q: When should I replace my Ga-Force X coalescing cartridge?
A:
We recommend a change-out when the differential pressure reaches 0.6 to 0.9 bar (8–13psi). Operating beyond this point can lead to “re-entrainment,” where the high-velocity gas picks up the collected liquid and carries it downstream.

Q: Can the Ga-Force X handle “Slug” loading of liquids?
A:
Coalescers are designed for aerosols and mists. If your system experiences heavy liquid “slugs,” we recommend installing a K Filter Bulk Separator or Knock-out Pot upstream of the Ga-Force X to extend the cartridge’s life.

Direct Cross-Reference Key
Switching from Pall? Replace SepraSol™* with K Filter Ga-Force X.
Switching from PECO? Replace PEACH PCHG with K Filter Ga-Force X. Switching from Parker? Replace V-Series with K Filter Hy-Sepra X.
Switching from Jonell*? Replace JPMG with K Filter Ga-Force X.

*Brand name is used only for reference

Scroll to Top
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.