Brain Series V module
Absolute Brain Series V-Module: High-Efficiency & High-Capacity Filtration for EMEA Healthcare
Absolute Brain Series V-Module represents the pinnacle of air sterilization technology. Specifically engineered for the rigorous demands of hospitals, laboratories, and pharmaceutical cleanrooms across Europe, the Middle East, and Africa, these filters deliver 99.99% efficiency at 0.3 microns.
Whether managing high-airflow fluctuations in modern European surgical suites or ensuring dust-free sterility in Middle Eastern medical hubs, the V-Module provides unmatched protection with a low pressure drop for optimized energy consumption.
Brain series V module absolute filters are improving indoor air quality by removing toxic gas, bacteria, viruses, and mold spores. Brain series V module absolute filters are suitable for safe change canister housing, bag-in-bag-out units, or module-in-duct housing.
Advanced Engineering & Composition.
Nano-Silver Fiberglass Media: Incorporates water-repellent and fire-retardant micro-fiberglass enhanced with nano-silver technology for active antibacterial protection.
Equal Spacer Technology: Utilizes thermoplastic spacers to ensure uniform airflow and structural integrity under high-pressure conditions.
Sterile Sealing: Finished with an antibacterial sealant to prevent bypass leakage, ensuring a 100% airtight fit in housing ducts and diffusers.
Engineering Excellence for Hospital Infrastructure
- Optimized for BIBO: Designed with rounded corners and a robust frame to prevent bag tears during Bag-In-Bag-Out (BIBO) safe-change procedures—critical for biosafety labs and oncology departments.
Our Key Features
- Absolute efficiency
- Available in either a gasket or gel seal configuration.
- Minimum efficiency: 99.99% @ 0.3 microns
- High strength
- Light weight
- V-bank design
- High airflow capacities, up to 2400 cfm (4000 m³/hr) airflow
- Low pressure drops
- Optimized
- Compact construction
- Halogen-free
Application
- Air Inlet (Clean Rooms, Operating Theatres, Laboratories, etc.)
- Industrial Processes (Microelectronics, Food Industry, Optics, Pharmaceutical Industry, Fine Chemistry, etc.)
- Treatment of Dangerous Substances (Asbestos, Metal dust, Bacteria, Viruses, Radioactive Particles).
Versatile Installation & Applications
Designed for seamless integration into diverse HVAC architectures, the Brain Series V-Module is compatible with:
Safe-Change (BIBO) Systems: Critical for high-containment labs (BSL-3/4) and infectious disease wards.
Module-in-Duct Housing: Ideal for centralized hospital ventilation.
Terminal Diffusers: Providing localized sterility for operating theaters and neonatal units.
Technical Data
- Compact Multi herds Absolute Filter
- Very High Efficiency
- Large Flow
- Framed Galvanized Steel with handle
- Separators: Thermoplastic glue beads.
- Sealant: Polyurethane
- Gasket: Bio component polyurethane
- MPPS efficiency: 85%, 99.95% and 99.995%
- EN 1822 Class: E10, H13 and H14.
- Recommended Final Pressure Loss: 600 Pa.
- Temperature: 80ºC in continuous service.
______________________________________________________________________________________________________________________________________________
Frequently Asked Questions (FAQ)
1. Does the Brain Series V-Module meet European filtration standards?
Yes. The V-Module is engineered to meet and exceed EN 1822 standards (H13/H14 classification), which is the primary benchmark for HEPA filtration in European and Middle Eastern healthcare facilities.
2. How does the filter perform in the high-dust environments of the Middle East and Africa?
The V-Module features water-repellent nano-silver media and a high surface area V-bank design. This allows it to handle higher dust loading while maintaining a low pressure drop, extending the filter life even in regions prone to seasonal sandstorms or high particulate matter.
3. Can this filter eliminate airborne viruses and bacteria?
Absolutely. With a 99.99% efficiency rating and integrated Nano-Silver technology, the filter not only captures sub-micron pathogens (including viruses, bacteria, and mold spores) but also inhibits microbial growth on the filter media itself.
4. Is it suitable for “Bag-In-Bag-Out” (BIBO) safety protocols?
Yes. The Brain Series V-Module is specifically designed for Safe-Change canister housing and Bag-In-Bag-Out units. This ensures that maintenance staff in high-risk environments can replace filters without coming into contact with captured biohazards.
5. How does this filter contribute to “Green Hospital” initiatives?
By utilizing Equal Spacer Technology and mini-pleated media, the V-Module minimizes resistance to airflow. This reduces the energy load on HVAC fans, helping hospitals in the EU and beyond meet sustainability targets and reduce operational costs
6. Can the Absolute Brain Series V-Module handle the extreme heat of the Middle East?
Yes. These filters are rated for continuous operation at temperatures up to 70°C. For specialized sterilization processes (like depyrogenation), we also offer high-temperature versions that can withstand even greater thermal stress.
7. Are custom sizes available for older European hospital renovations?
While comes in standard 610x610mm and 305x610mm modules, customized versions (including stainless steel frames) are available on request to fit legacy air handling units common in older European medical facilities.
8. Why is “Low Pressure Drop” important for hospital procurement?
Lower pressure drop means the HVAC fans do not have to work as hard to push air through the filter. For 24/7 hospital operations, this translates to significantly lower electricity bills and a smaller carbon footprint, aligning with EU energy regulations.
Key Benefits at a Glance
| Feature | Benefit |
| 99.99% @ 0.3μm | Guaranteed sterility for surgical and cleanroom environments. |
| Nano-Silver Media | Active antimicrobial properties to prevent “filter-breeding” of bacteria. |
| V-Module Design | Handles high/fluctuating airflow without sacrificing efficiency. |
| Fire Retardant | Meets international safety codes for healthcare infrastructure. |
______________________________________________________________________________________________________________________________________________
9. Is it possible Braine Series V model HEPA can customised size?
Absolutely. The Absolute Brain Series V-Module is designed with flexibility in mind to ensure a perfect fit for the diverse HVAC systems found in hospitals and clinics across the EMEA region.
While there are “standard” industry sizes (such as 610x610mm or 305x610mm), we understand that older hospital infrastructures in Europe or custom-built medical facilities in the Middle East often require unique dimensions
Customization Options for the Brain Series V-Module
Bespoke Dimensions: We can manufacture the V-Module in custom widths and heights to fit non-standard housing or legacy air handling units (AHUs).
Variable Depths: Standard depths are typically 292mm, but adjustments can be made depending on the specific airflow requirements and space constraints of your ducting.
Frame Material Selection: Depending on your environment (e.g., high humidity in coastal Africa or sterile chemical labs in Europe), you can choose from:
Galvanized Steel (Standard/Durable)
Anodized Aluminum (Lightweight/Corrosion-resistant)
Stainless Steel (304/316L) (Highest hygiene/Chemical resistance)
ABS Plastic (Incinerable/Lightweight)
Gasket & Flange Variations: Customization of the sealing edge (Single flange, Double flange, or No flange) and gasket material (Polyurethane, EPDM, or High-Heat Silicone) to ensure a 100% leak-proof installation.
Why Customize?
Custom-sized filters eliminate the need for expensive ductwork modifications. By providing a “drop-in” replacement that matches your exact specifications, you maintain the sterility-level air filtration and 99.99% efficiency without compromising the structural integrity of your existing ventilation system.
______________________________________________________________________________________________________________________________________________
Why the Brain Series V-Module is Ideal for Containment?
1. Integration with BIBO (Bag-In-Bag-Out) Systems
For containment applications—such as BSL-3/BSL-4 laboratories or Isolation Wards—filter changes must be performed without exposing maintenance staff to the airstream. The V-Module is designed with.
Reinforced Frame Integrity: To withstand the pressure of gasket-seal or fluid-seal housings.
Rounded Edges: To prevent tearing the protective PVC bags used during the “Bag-In-Bag-Out” procedure.
2. Pathogen and Toxic Gas Capture
Containment isn’t just about dust; it’s about micro-pathogens.
- Viral/Bacterial Capture: The 99.99% efficiency at 0.3 microns ensures that even the smallest airborne droplets (nuclei) carrying viruses are trapped
- Nano-Silver Protection: The antimicrobial properties of the nano-silver media prevent “bio-nesting,” where captured bacteria might otherwise grow on the filter surface over time.
3. Resistance to High/Fluctuating Airflow
In containment zones, pressure differentials (negative pressure) must be strictly maintained. The V-Module’s Equal Spacer Technology ensures the filter media remains stable and doesn’t “flex” or fail under the fluctuating air pressures common in high-containment exhaust systems.
4. Leak-Proof Sealing
The use of antibacterial sealant around the entire media pack ensures there are no bypass paths. In a containment scenario, a leak of even is unacceptable; the Brain Series V-Module is individually scan-tested to guarantee a 100% leak-free seal.
______________________________________________________________________________________________________________________________________________
FAQ for Containment Standards
Q: Can this filter be used in Negative Pressure Rooms?
A: Yes. It is the preferred choice for the exhaust side of negative pressure environments to ensure that all air leaving the contaminated zone is sterile.
Q: Is it resistant to decontamination gases like Vaporized Hydrogen Peroxide (VHP)?
A: The micro-fiberglass media and thermoplastic spacers are highly resistant to the chemicals typically used for room sterilization in European and Middle Eastern hospitals, ensuring the filter does not degrade during cleaning cycles.
Q: Does it meet the ISO 14644 cleanroom standards?
A: Absolutely. It is designed to maintain ISO Class 5 environments and higher, which is the benchmark for high-containment sterility.